dc.contributor.author |
Thusharika, M.M.P. |
|
dc.contributor.author |
Somasiri, D.A.D.H. |
|
dc.contributor.author |
Athukorala, G.I.D.D.A.D. |
|
dc.contributor.author |
Sunil-Chandra, N.P. |
|
dc.date.accessioned |
2016-05-31T08:11:58Z |
|
dc.date.available |
2016-05-31T08:11:58Z |
|
dc.date.issued |
2003 |
|
dc.identifier.citation |
The Bulletin of the Sri Lanka College of Microbiologists. 2003; 01(1): 18 |
en_US |
dc.identifier.issn |
1391-930x |
|
dc.identifier.uri |
http://repository.kln.ac.lk/handle/123456789/13317 |
|
dc.description |
Oral Presentation (OP 02) The bulletin of the Sri Lanka College of Microbiologists, 19th-21st August 2003, Colombo |
en_US |
dc.description.abstract |
OBJECTIVE: To assess the potential risk of nosocomial infection DESIGN: Descriptive, prospective controlled study over a period of 17 days in November 2002. SETTING: Special care baby unit, labour room, surgical wards 1 and 2. theatre and the intensive care unit of the Teaching Hospital, Ragama. METHODS: Thirty hand imprints including 13 doctors, 17 other health care workers and 85 swabs from 6 stethescopes and 31 medical equipment were taken randomly. Six health care workers and 3 stethoscopes were included for a control study. Cultures were identified and antibiotic sensitivity tests were performed. RESULTS: 97% (29/30) of hand imprints were contaminated. The main pathogen isolated was Staphylococcus aureus (43%). 60% of Staphylococcus aureus strains were methicillin resistant (MRSA) and 33% of MRS A were also resistant to Vancomycin. Vancomycin resistance needs confirmation. There were Klebsiella spp, E. coli and other coliforms in 27%, Pseudomonas spp in 13% and Candida spp in 3%. 73 % (51/85) of equipment were contaminated. There were Staphylococcus aureus in 29%, E. coli, Klebsiella species and other coliforms in 22%, Pseudomonas species in 13%, arid Candida species in 1%. Of the stethescopes. 33% of bells and diaphragms had Staphylococcus aureus. There was complete elimination of organisms from both hands and stethoscopes of the control following the useof4%hibitane CONCLUSION: This study clearly demonstrates the burden of bacterial contamination among hands of healthcare workers in Sri Lanka. |
en_US |
dc.language.iso |
en_US |
en_US |
dc.publisher |
Sri Lanka College of Microbiologists |
en_US |
dc.subject |
nosocomial infections |
en_US |
dc.title |
A study on the bio-burden of doctors' and other health care workers' hands, stethoscopes and other medical devices in a Sri Lankan set up - Potential risk of nosocomial infections? |
en_US |
dc.type |
Article |
en_US |