Digital Repository

Lung function of fuel handlers exposed to volatile organic compounds

Show simple item record

dc.contributor.author Wadasinghe, D.
dc.contributor.author Warnakulasuriya, T.
dc.contributor.author Medagoda, K.
dc.contributor.author Kottahachchi, D.
dc.contributor.author Luke, D.
dc.contributor.author Ariyawansa, J.
dc.contributor.author Rathnayake, P.
dc.contributor.author Dissanayake, T.
dc.contributor.author de Silva, D.
dc.contributor.author Amarasiri, L.
dc.contributor.author Devanarayana, N.M.
dc.contributor.author Scheepers, P.
dc.date.accessioned 2021-02-12T07:31:48Z
dc.date.available 2021-02-12T07:31:48Z
dc.date.issued 2020
dc.identifier.citation Journal of the Ceylon College of Physicians. 2020; 51(Supplement 1): 34. en_US
dc.identifier.issn 2448-9514
dc.identifier.issn 0379-802X
dc.identifier.uri http://repository.kln.ac.lk/handle/123456789/21955
dc.description Poster Presentation Abstract (PP11), College of Physicians Annual Conference 2020, 19th-21st November. Colombo, Sri Lanka. en_US
dc.description.abstract INTRODUCTION AND OBJECTIVES: The respiratory system is a target for effects from air pollutants, including vehicle emissions composed of volatile organic compounds (VOC), particulate matter and other noxious gasses. Our objective was to study the association between selected VOCs and lung function in a cohort of fuel handlers. METHOD: Forty-four fuel handlers (men) from the Gampaha district of Sri Lanka aged 19-65 years were selected using consecutive sampling with a group of 38 males matched by age, without occupational exposure to fuel recruited as controls. Spirometry was performed using a Vitalograph Alpha Touch spirometer, according to ATS guidelines. Pre and post shift VOC levels were measured in end exhaled air samples. RESULTS: The spirometry parameters were not significantly different between the two groups but obstructive (47.72% vs.34.21%) and restrictive ventilatory patterns (31.81% vs. 21.05%) were higher among the fuel handlers. FVC and FEV1 negatively correlated with age (r=-0.672, p<0.001 and r=-6.888, p<0.001 respectively) and number of days of exposure (r=-0.329, p=0.033 and r=-0.306, p=0.049 respectively). Among the fuel handler's, benzene exposure negatively correlated with FVC (r=-0.552, p=0.012) and FEV1 (r=-0.476, p=0.034) and toluene exposure negatively correlated with PEF (r=-0.488, p=0.034). Although levels of all VOCs measured were significantly low among the controls, toluene exposure levels negatively correlated with all spirometry parameters (p<0.05). CONCLUSIONS: A decline in lung function is seen with more days of exposure as a fuel handler. The different vVOCs· affect the volume parameters and flow parameters uniquely and even non-occupational exposure causes an alteration of spirometry parameters among adult males. en_US
dc.language.iso en_US en_US
dc.publisher Journal of the Ceylon College of Physicians en_US
dc.subject Lung function en_US
dc.title Lung function of fuel handlers exposed to volatile organic compounds en_US
dc.type Conference abstract en_US


Files in this item

This item appears in the following Collection(s)

  • Conference Papers
    Papers presented at local and international conferences by the Staff of the Faculty of Medicine

Show simple item record

Search Digital Repository


Browse

My Account