Digital Repository

Obtaining Patient Torso Geometry for the Design of Scoliosis Braces. A Study of the Accuracy and Repeatability of Handheld 3D Scanners

Show simple item record

dc.contributor.author Sanz-Pena, I.
dc.contributor.author Arachchi, S.
dc.contributor.author Curtis-Woodcock, N.
dc.contributor.author Silva, P.
dc.contributor.author McGregor, A. H.
dc.contributor.author Newell, N.
dc.date.accessioned 2022-05-19T04:55:52Z
dc.date.available 2022-05-19T04:55:52Z
dc.date.issued 2022
dc.identifier.citation Sanz-Pena, I., Arachchi, S., Curtis-Woodcock, N., Silva, P., McGregor, A. H., & Newell, N. (2022). Obtaining Patient Torso Geometry for the Design of Scoliosis Braces. A Study of the Accuracy and Repeatability of Handheld 3D Scanners. Prosthetics and orthotics international, 10.1097/PXR.0000000000000118. Advance online publication. https://doi.org/10.1097/PXR.0000000000000118 en_US
dc.identifier.uri http://repository.kln.ac.lk/handle/123456789/24579
dc.description.abstract Objective: Obtaining patient geometry is crucial in scoliosis brace design for patients with adolescent idiopathic scoliosis. Advances in 3D scanning technologies provide the opportunity to obtain patient geometries quickly with fewer resources during the design process compared with the plaster-cast method. This study assesses the accuracy and repeatability of such technologies for this application. Methods: The accuracy and repeatability of three different handheld scanners and phone-photogrammetry was assessed using different mesh generation software. Twenty-four scans of a single subject's torso were analyzed for accuracy and repeatability based on anatomical landmark distances and surface deviation maps. Results: Mark II and Structure ST01 scanners showed maximum mean surface deviations of 1.74 ± 3.63 mm and 1.64 ± 3.06 mm, respectively. Deviations were lower for the Peel 1 scanner (maximum of -0.35 ± 2.8 mm) but higher with the use of phone-photogrammetry (maximum of -5.1 ± 4.8 mm). The mean absolute errors of anatomical landmark distance measurements from torso meshes obtained with the Peel 1, Mark II, and ST01 scanners were all within 9.3 mm (3.6%), whereas phone-photogrammetry errors were as high as 18 mm (7%). Conclusions: Low-cost Mark II and ST01 scanners are recommended for obtaining torso geometries because of their accuracy and repeatability. Subject's breathing/movement affects the resultant geometry around the abdominal and anterolateral regions. en_US
dc.publisher Prosthetics and orthotics international en_US
dc.subject 3D scanner, scan accuracy, torso geometry, scoliosis brace, adolescent idiopathic scoliosis en_US
dc.title Obtaining Patient Torso Geometry for the Design of Scoliosis Braces. A Study of the Accuracy and Repeatability of Handheld 3D Scanners en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search Digital Repository


Browse

My Account