Digital Repository

Comparative Analysis of Albumin Measurement by Bromocresol Green Versus Capillary Zone Electrophoresis

Show simple item record

dc.contributor.author Harshanee, T.
dc.contributor.author Jayasekara, D.
dc.contributor.author Fernando, K.
dc.contributor.author Kulasinghe, M.
dc.contributor.author Silva, P.
dc.contributor.author Bandara, S.
dc.contributor.author Dayanath, B.K.P.T.
dc.date.accessioned 2024-09-11T08:30:26Z
dc.date.available 2024-09-11T08:30:26Z
dc.date.issued 2024
dc.identifier.citation College of Chemical Pathologists of Sri Lanka, 9th Annual Academic Sessions 2024. 2024; 9: 92. en_US
dc.identifier.uri http://repository.kln.ac.lk/handle/123456789/28322
dc.description Abstracts of E-Posters(RP 05), 9th Annual Academic Sessions, College of Chemical Pathologists of Sri lanka, 13th and 14th July 2024, Colombo, Sri Lanka. en_US
dc.description.abstract INTRODUCTION Quantitative assessment of albumin and globulins in serum protein electrophoresis (SPE) relies on the calculation derived from total protein measurements obtained from the biuret assay. Validation of these results involves comparing sample albumin concentration assessed using the bromocresol green (BCG) method to those obtained from capillary zone electrophoresis (CZE). This study aimed to assess the relationship between albumin values derived from SPE and routine spectrophotometric analysis with BCG method, and to establish a cut-off value to identify significant differences between the two values in SPE validation process. METHODS 187 serum samples were subjected to total protein assessment by biuret method, albumin assessment by BCG method, and SPE by CZE method. SPE derived albumin level using total protein values and BCG method indicated albumin values were analyzed by correlation analysis. The standard error for the difference (SEdif) between the two albumin results were calculated, with statistical significance set at p <0.05. Internal and external quality assessments were deemed acceptable for all three analytical procedures. RESULTS Mean albumin levels obtained via BCG and CZE methods were 38.3 mg/dL and 33.2 mg/dL, respectively, indicating a negative bias for the latter method. A strong correlation (r=0.844, p<0.001) was observed between albumin levels measured by BCG and CZE methods, with Bland-Altman analysis revealing an average negative bias of 5 mg/dL. Using SEdif at 95% significance, the maximum acceptable difference between the two albumin values was determined to be -5.4 mg/dL. CONCLUSIONS BCG method yielded higher albumin results compared to CZE method. This positive bias could be attributed to potential lack of specificity of BCG assay for albumin. A maximum allowable difference of 5.5 mg/dL between the two methods is suggested. Exceeding this threshold indicates potential issues with either the BCG albumin assay, biuret total protein assay, or SPE assay, necessitating further investigation for assay reliability, particularly in reporting SPE by CZE. en_US
dc.language.iso en en_US
dc.publisher College of Chemical Pathologists of Sri Lanka en_US
dc.subject Bromocresol green en_US
dc.subject Capillary electrophoresis en_US
dc.subject Dye-binding en_US
dc.subject Albumin en_US
dc.subject Correlation en_US
dc.title Comparative Analysis of Albumin Measurement by Bromocresol Green Versus Capillary Zone Electrophoresis en_US
dc.type Article en_US